Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody

50X Concentration, Azide Free
Catalog # Availability Size / Price Qty
NLLC4770R
Detection of TRA-1-60(R) in Live BG01V Human Embryonic Stem Cells.
1 Image
Product Details
Procedure
Citations (2)
FAQs
Reviews (3)

Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody Summary

Kit Summary

To detect TRA-1-60(R) expression in live cells by immunocytochemical staining.

Why confirm marker expression in live cells before colony selection?

Maintaining pluripotent human embryonic stem cells and deriving induced pluripotent stem cells require colony selection and cell expansion. Picking colonies that contain pluripotent stem cells is typically achieved by manually analyzing colony morphology. Unfortunately, this critical process is time-consuming and labor-intensive.

In addition, morphology-based colony selection does not consistently guarantee pluripotent starting populations, since cells can fail to be fully reprogrammed or can naturally differentiate within a colony.

To address this need, R&D Systems offers GloLIVE™ antibodies that allow researchers to confirm stem cell marker expression in live cells before colony selection.

Live pluripotent stem cell imaging:

  • Promotes the selection of high quality, undifferentiated stem cell colonies to reduce experimental variation.
  • Verifies stem cell pluripotency in 30 minutes, ensuring efficient use of time and reagents.
  • Allows for the continued culture of pluripotent cells with no adverse effects on cell proliferation or stemness following staining.

 

Antibody Components
  • GloLIVE NL557-conjugated Mouse Anti-Human TRA-1-60(R) Monoclonal Antibody.
  • Supplied as 50X concentration of antibody in 0.5 mL PBS

Azide free and endotoxin tested (= 5 EU/mL), this antibody can be used for 12 tests, if a staining volume of 2 mL is used.

Specifications

Shipping Conditions
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Storage
Store the unopened product at 2 - 8° C. Do not use past expiration date. Protect from light.
Species
Human

Limitations

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.

Product Datasheets

You must select a language.

x

Scientific Data

Detection of TRA-1-60(R) in Live BG01V Human Embryonic Stem Cells. The stem cell marker TRA-1-60(R) was visualized in live BG01V human embryonic stem cells using a GloLIVE NL557-conjugated Mouse Anti-Human TRA-1-60(R) Monoclonal Antibody (Catalog # NLLC4770R; red). The nuclei were counterstained with Hoechst 33342 (blue). Positive staining for TRA-1-60(R) in human stem cells is an indicator of pluripotency.

Background: TRA-1-60(R)

TRA-1-60 is a monoclonal antibody raised against a cell surface antigen of human embryonal carcinoma (EC) cells (1). The TRA-1-60 epitope is also found on human embryonic stem (ES) cells and primordial germ cells, and TRA-1-60 serves as a serum marker in patients with germ cell tumors (2‑4). Investigation into the identity of the TRA-1-60 epitope demonstrated that it is a carbohydrate carried by a cell surface, sialylated, keratan sulfate proteoglycan (5). Subsequent evidence implicated podocalyxin as a carrier for the TRA-1-60 epitope (6).

References
  1. Andrews, P. et al. (1984) Hybridoma 3:347.
  2. Thomson, J. et al. (1998) Science 282:1145.
  3. Giwercman, A. et al. (1993) Cancer 72:1308.
  4. Marrink, J. et al. (1991) Int. J. Cancer 49:368.
  5. Badcock, G. et al. (1999) Cancer Res. 59:4715.
  6. Schopperle, W. and W. DeWolf (2007) Stem Cells 25:723.
Long Name
Tumor-related Antigen-1-60 [R]
Entrez Gene IDs
5420 (Human)
Alternate Names
RA160; TRA160(R); TRA-1-60(R); tra61

Assay Procedure

Refer to the product datasheet for complete product details.

Briefly, TRA-1-60(R) expression can be verified in live cells prior to colony selection or experimentation using this simple procedure:

  • Add the TRA-1-60(R) antibody directly to the media of cultured cells
  • Wash the cells after a 30 minute incubation
  • Select for and expand TRA-1-60(R)-positive colonies
 
 

Precautions

Use aseptic technique and sterile culturing conditions to prevent contamination.

Reagents Provided

GloLIVE NL557-conjugated Mouse Anti-Human TRA-1-60(R) Monoclonal Antibody. (Catalog # NLLC4770R):

Other Supplies Required

Reagents

  • Stem cell culture media

Materials

  • Human or mouse pluripotent stem cells
  • Pipettes and pipette tips
  • Serological pipette

Equipment

  • 37 °C and 5% CO2 incubator
  • Fluorescence microscope
 

Live Cell Immunocytochemistry Procedure Overview

To ensure sterility of cultures, all steps should be performed under sterile conditions.


Add primary antibody in appropriate culture media to cells.
 
  1. Add fluorochrome-conjugated primary antibody in appropriate culture media to cells.
  2. Incubate for 30 minutes.

Replace with fresh culture media
 
  1. Replace with fresh culture media.

Visualize using a fluorescence microscope
 
  1. Visualize using a fluorescence microscope.

Note: Culture with GloLIVE antibodies does not appear to affect cell proliferation or stemness as assayed by proliferation curves for 3 days post-antibody incubation and expression levels of TRA-1-60(R) and Oct-3/4.

Citations for Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody

R&D Systems personnel manually curate a database that contains references using R&D Systems products. The data collected includes not only links to publications in PubMed, but also provides information about sample types, species, and experimental conditions.

2 Citations: Showing 1 - 2
Filter your results:

Filter by:

  1. Robust and highly efficient hiPSC generation from patient non-mobilized peripheral blood-derived CD34+ cells using the auto-erasable Sendai virus vector
    Authors: T Okumura, Y Horie, CY Lai, HT Lin, H Shoda, B Natsumoto, K Fujio, E Kumaki, T Okano, S Ono, K Tanita, T Morio, H Kanegane, H Hasegawa, F Mizoguchi, K Kawahata, H Kohsaka, H Moritake, H Nunoi, H Waki, SI Tamaru, T Sasako, T Yamauchi, T Kadowaki, H Tanaka, S Kitanaka, K Nishimura, M Ohtaka, M Nakanishi, M Otsu
    Stem Cell Res Ther, 2019-06-24;10(1):185.  2019-06-24
  2. Amenable epigenetic traits of dental pulp stem cells underlie high capability of xeno-free episomal reprogramming
    Authors: S Thekkepara, S Sriram, S Subramania, S Cheng, WK Ong, S Rozen, NHA Kasim, S Sugii
    Stem Cell Res Ther, 2018-03-20;9(1):68.  2018-03-20

FAQs

  1. What is the recommended starting confluence to observe staining?

    • The optimal confluence would depend on the purpose of the staining. If the plan is to use all the cells in the flask after they have proliferated, then one can wait for the cells to become confluent or almost confluent (80-90% confluent) and then check the staining. If the goal is to to check on the cells mid-way through their growth and there are sufficient cells in the flask, one could check the staining then as well. The staining is not dependent on how many cells are in the flask, as long as there are sufficient cells.

View all Antibody FAQs

Reviews for Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody

Average Rating: 5 (Based on 3 Reviews)

5 Star
100%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%

Have you used Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review

Filter by:


Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody
By Anonymous on 03/04/2022

Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody
By Anonymous on 07/22/2021

Human GloLIVE TRA-1-60(R) NorthernLights™ NL557-conjugated Antibody
By Anonymous on 07/02/2021