Human ROBO4 Antibody Summary

Species Reactivity
Human
Specificity
Detects human ROBO4 in direct ELISAs and Western blots. In direct ELISAs, no cross-reactivity with recombinant rat ROBO1, recombinant human (rh) ROBO2, or rhROBO3 is observed.
Source
Monoclonal Mouse IgG2A Clone # 265703
Purification
Protein A or G purified from hybridoma culture supernatant
Immunogen
Mouse myeloma cell line NS0-derived recombinant human ROBO4
Gln28-Arg467
Accession # Q8WZ75
Formulation
Lyophilized from a 0.2 μm filtered solution in PBS with Trehalose. *Small pack size (SP) is supplied either lyophilized or as a 0.2 µm filtered solution in PBS.
Purity
Protein A or G purified from hybridoma culture supernatant

Applications

Recommended Concentration
Sample
Western Blot
1 µg/mL
Recombinant Human ROBO4
Flow Cytometry
2.5 µg/106 cells
HUVEC human umbilical vein endothelial cells
CyTOF-ready
Ready to be labeled using established conjugation methods. No BSA or other carrier proteins that could interfere with conjugation.
 

Please Note: Optimal dilutions should be determined by each laboratory for each application. General Protocols are available in the Technical Information section on our website.

Reconstitution Calculator

Reconstitution Calculator

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial. Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

=
÷

Preparation and Storage

Reconstitution
Reconstitute at 0.5 mg/mL in sterile PBS.
Loading...
Shipping
The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below. *Small pack size (SP) is shipped with polar packs. Upon receipt, store it immediately at -20 to -70 °C
Stability & Storage
Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
  • 12 months from date of receipt, -20 to -70 °C as supplied.
  • 1 month, 2 to 8 °C under sterile conditions after reconstitution.
  • 6 months, -20 to -70 °C under sterile conditions after reconstitution.

Background: ROBO4

ROBO4, also called magic roundabout, is a ~150 kDa glycoprotein belonging to the ROBO family (1). ROBOs are molecular guidance receptors that typically interact with Slit ligands to regulate axon guidance and neuronal migration (2). Unlike other family members, ROBO4 is mainly restricted to the vascular endothelium (1, 2). Expression in early hematopoietic progenitors is also reported (3). The human ROBO4 cDNA encodes 1012 amino acids (aa), including a 27 aa signal sequence, a 440 aa extracellular domain (ECD) containing two C2‑type Ig domains and two fibronectin type III (FNIII) domains, a transmembrane domain and an intracellular domain. ROBO4 diverges from other ROBOs in the number of Ig, FNIII and cytoplasmic CC domains (1, 4). Within the ECD, human ROBO4 shares 80%, 80%, 87% and 88% aa identity with mouse, rat, bovine and canine ROBO4, respectively. Vascular endothelial ROBO4 is expressed at highest levels in during development and vascular remodeling, including tumor angiogenesis (1, 2, 4 ‑ 6). It is proposed to contribute to vascular stability. Consistent with this, endogenous ROBO4 is concentrated in the vascular stalk and sprouts rather than tip cells and appears to protect newly formed blood vessels against VEGF‑induced vascular leak (6 ‑ 9). ROBO4 binding of Slit proteins has been variably reported, and when detected may be mediated by ROBO4/ROBO1 heterodimers (2, 4 ‑ 7, 9 ‑ 13). ROBO4 is also variably reported to stimulate or inhibit cell migration or filopodia formation (2, 4 ‑ 13). Effects on cell movement may be mediated through intracellular binding of WASP‑, Ras/Rac/Rho‑, Mena‑, Src‑ or Paxillin‑related proteins, all of which affect the cytoskeleton (5 ‑ 7, 10 ‑ 12). Recombinant soluble ROBO4 ECD can antagonize endothelial cell migration and in vivo angiogenesis (13). 

References
  1. Huminiecki, L. et al. (2002) Genomics 79:547.
  2. Legg, J.A. et al. (2008) Angiogenesis 11:13.
  3. Shibata, F. et al. (2009) Stem Cells 27:183.
  4. Park, K.W. et al. (2003) Dev. Biol. 261:251.
  5. Seth, P. et al. (2005) Biochem. Biophys. Res. Commun. 332:533.
  6. Jones, C.A. et al. (2008) Nat. Med. 14:448.
  7. Jones, C.A. et al. (2009) Nat. Cell Biol. 11:1325.
  8. Chen, H. et al. (2010) Adv. Exp. Med. Biol. 664:457.
  9. London, N.R. et al. (2009) J. Thromb. Haemost. 7:57.
  10. Verissimo, A.R. et al. (2009) Biochem. Soc. Trans. 37:1214.
  11. Sheldon, H. et al. (2009) FASEB J. 23:513.
  12. Kaur, S. et al. (2008) BMC Cell Biol. 9:61.
  13. Suchting, S. et al. (2005) FASEB J. 19:121.
Long Name
Roundabout Homolog 4
Entrez Gene IDs
54538 (Human); 74144 (Mouse)
Alternate Names
ECSM4; FLJ20798; Magic roundabout; MGC133352; MGC133353; MRB; ROBO4; roundabout homolog 4; roundabout homolog 4, magic roundabout (Drosophila)

Product Datasheets

You must select a language.

x

Citations for Human ROBO4 Antibody

R&D Systems personnel manually curate a database that contains references using R&D Systems products. The data collected includes not only links to publications in PubMed, but also provides information about sample types, species, and experimental conditions.

3 Citations: Showing 1 - 3
Filter your results:

Filter by:

  1. Robo4 is constitutively shed by ADAMs from endothelial cells and the shed Robo4 functions to inhibit Slit3-induced angiogenesis
    Authors: W Xiao, A Pinilla-Ba, J Faulkner, X Song, P Prabhakar, H Qiu, KW Moremen, A Ludwig, PJ Dempsey, P Azadi, L Wang
    Scientific Reports, 2022-03-14;12(1):4352.
    Species: Human, Mouse
    Sample Types: Cell Lysates
    Applications: Western Blot
  2. Slit2 signaling through Robo1 and Robo2 is required for retinal neovascularization.
    Authors: Rama N, Dubrac A, Mathivet T, Ni Charthaigh R, Genet G, Cristofaro B, Pibouin-Fragner L, Ma L, Eichmann A, Chedotal A
    Nat Med, 2015-04-20;21(5):483-91.
    Species: Human
    Sample Types: Cell Lysates
    Applications: Western Blot
  3. The axonal repellent Slit2 inhibits pericyte migration: potential implications in angiogenesis.
    Authors: Guijarro-Munoz I, Cuesta AM, Alvarez-Cienfuegos A, Geng JG, Alvarez-Vallina L, Sanz L
    Exp. Cell Res., 2011-12-14;318(4):371-8.
    Species: Human
    Sample Types: Cell Lysates
    Applications: Immunoprecipitation

FAQs

No product specific FAQs exist for this product, however you may

View all Antibody FAQs
Loading...

Reviews for Human ROBO4 Antibody

Average Rating: 3.5 (Based on 2 Reviews)

5 Star
0%
4 Star
50%
3 Star
50%
2 Star
0%
1 Star
0%

Have you used Human ROBO4 Antibody?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review

Filter by:


Human ROBO4 Antibody
By Anonymous on 01/03/2020
Application: Microarrays Sample Tested: EDTA Plasma Species: Human

Human ROBO4 Antibody
By Anonymous on 02/21/2019
Application: MiAr Sample Tested: EDTA Plasma Species: Human